What is the difference between EPS and UPS?

What is the difference between EPS power supply and UPS power supply?

1, different application areas

In China, EPS power is mainly used for power equipment in the fire protection industry, emphasizing the ability to continuously supply power. The UPS power supply is generally used for precision instrument loads (such as computers, servers and other IT industry equipment), requiring high quality power supply, emphasizing requirements on inverter switching time, output voltage, frequency stability, and pureness of the output waveform.

2, different functions

Both the EPS power supply and the UPS power supply have a mains bypass and an inverter circuit. The functional difference is that the EPS power supply has a continuous power supply function, and generally does not require a high switching time, and special applications require certain requirements. Multiple outputs and monitoring and detection of each output and individual battery. Daily emphasis is placed on bypass power supply, when the utility power fails, it turns to inverter power supply, and the power utilization rate is high. UPS power supply such as online only one way total output, generally emphasizes its three major functions: (A) voltage stabilization (B) uninterrupted power supply (C) can clean the mains. Daily emphasis on rectification / inverter double conversion circuit power supply, inverter failure or overload is only transferred to the bypass supply, power utilization is not high (usually 80% -90%). However, in countries abroad such as Europe and the United States where the power grid and power supply are relatively complete, in order to save energy, some sites that use UPS have been replaced by EPS with very short inverter switching time (less than 10 ms). EPS power brands mainly include Berk EPS (switching time less than 1.8ms), Beijing Power Source EPS, and Genesys EPS.

3, different structure

The EPS power inverter has a large amount of redundancy. The incoming line cabinet and outgoing line cabinet are all inside the EPS, and the motor load has frequency conversion start. The casing and the wires are fire-retardant, and there are multiple paths of mutual investment, which can be linked with fire fighting. The inverter redundancy of the UPS power supply is relatively small and has nothing to do with fire protection. It does not need to be flame-retardant and has no mutual investment function. EPS power supply is generally perceptual and resistive. It can be equipped with motors, lighting, fans, pumps, etc. It is an emergency fire protection product. It is a dedicated emergency fire lighting power supply for emergency power supply. The UPS power load is a capacitive load. The main band device is generally a computer. It is mainly used in large-scale computer rooms to ensure uninterrupted power supply and voltage regulation.

Customized Solar Panel

Customized Solar Panel, 100watt solar panel,200watt solar panel, big solar panel, high efficiency high quality solar modules

different power customized and OEM logo customized solar panel


Customized solar panel data

solar cell type mono crystalline half cut cell
power range 50watt to max 700watt
size and weight different size and different weight if the power is different
solar panel type monofacial or bifacial
solar panel color sliver or black

Product details and pic

1 Jpg5 Png5 Png

Customized Solar Panel,Noncrystalline Solar Panel Module,Cheap Price Pv Solar Module,Solar Photovoltaic Pv Panel

PLIER(Suzhou) Photovoltaic Technology Co., Ltd. , https://www.pliersolarpanel.com