Model NO.: MV-BE41
-
Voltage: Low and Medium Voltage Cable
-
Insulation Material: Epr
-
Material Shape: Round Wire
-
Certification: ISO, CCC, CE, RoHS, UL, VDE
-
Brand: Yifang
-
Trademark: Yifang Cable
-
Specification: 2 AWG TO 4/0awg
-
HS Code: 8544601200
-
Application: Construction, Underground, Industrial
-
Current: DC & AC
-
Sheath Material: PVC
-
Wire Core Material: Round Aluminum or Copper Wire
-
Model: Mv-Be41
-
Standard: ASTM
-
Transport Package: Wooden or Wooden-Steel Drum
-
Origin: Zhengzhou, China
TRXLPE 35kV Primary URD Concentric Cable Neutral LLDPE Jacket AEIC CS8-07Â
1
ApplicationsFor use on single phase and three phase primary underground distribution systems operating at 15 kV phase to phase at 100 % and 133 % insulation level. Suitable for either direct burial or installation in ducts.
ConstructionCopper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
- Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
- Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
- Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
- Conforms to ANSI/ICEA T-34-664-2007 Test Method for Conducting Longitudinal Water Penetration.
Options
- EPR insulation
- Filled strand
- Cable core water blocking.
Notes
- Ampacities are based on the NEC.
- Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
- Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth Ï = 90, 100% load factor.
- Conduit in Air: Three cables per isolated conduit in air at 40 ºC operating at 105 ºC conductor (NEC Table 310.73).
Specification

Package and Delivery

Medical Device Wire
Medical Device Wire :The key requirements of modern medical connector include safety, reliability, small size and high speed performance. Since it is a small component in the overall design of any medical device, it can be considered that the connector is an important part of the medical equipment.
Common BV, RV line series
Silicone rubber insulated high temperature wire agr
High temperature braided wire AgRP with silicone rubber insulation and glass fiber
Silica gel high temperature control cable
Silicone rubber high voltage line agg 1kv-100kv
Teflon high voltage line 1kv-100kv
PFA Teflon insulated wire
FEP fluoroplastic high temperature line
PTFE fluoroplastic high temperature line
High temperature resistant control cable with Fluoroplastic insulation and sheath
Fire resistant and flame retardant control cable with PVC insulation sheath
Fire resistant line gn500 degree
Medical Device Wire
ShenZhen Antenk Electronics Co,Ltd , https://www.antenkwire.com