Size of conductor | Nominal thickness of insulation mm |
Mean overall diameter Upper limit mm |
Approx. Net weight per km Kg |
|
Nominal Cross-sectional area mm2 |
Number and diameter of wires No. /mm |
|||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Size of conductor | Nominal thickness Of insulation mm |
Size of Earth- Conduct -ivity Conductor No/mm |
Nominal thickness Of sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires mm |
Lower limit mm |
Upper Limit mm |
||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*9.6 | 4.7*11.0 | 92 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*10.5 | 5.4*12.5 | 115 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*12.5 | 6.2*14.5 | 170 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.1 | 5.8*14.5 | 7.4*18.0 | 255 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*16.5 | 8.0*20.0 | 340 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*21.0 | 9.6*25.5 | 550 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*24.5 | 11.0*29.5 | 790 |
Size of conductor | Nominal Thickness Of insulation mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross-sectional area mm2 |
Number and diameter of wires No/mm |
Lower Limit mm |
Upper Limit mm |
||
0.5 | 28/0.15 | 0.8 | 2.5X5.0 | 3.0X6.0 | 24 |
0.75 | 42/0.15 | 0.8 | 2.7X5.4 | 3.2X6.4 | 29 |
Size of conductor | Nominal Thickness Of insulation mm |
Mean overall diameter Upper limit mm |
Approx. Net weight per km Kg |
|
Nominal Cross-sectional area mm2 |
Number and diameter of wire No/mm |
|||
0.5 | 16/0.20 | 0.6 | 2.6 | 10 |
0.75 | 24/0.20 | 0.6 | 2.8 | 13 |
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5* | 30/0.25 | 0.7 | 3.5 | 20 |
2.5* | 50/0.25 | 0.8 | 4.2 | 32 |
4.0* | 56/0.30 | 0.8 | 4.8 | 49 |
Size of conductor | Nominal Thickness Of insulation mm |
Mean overall diameter of Each core Upper limit mm |
Approx. Net weight per km Kg |
|
Nominal Cross-sectional area mm2 |
Number and diameter of wires mm |
|||
0.5 | 16/0.20 | 0.6 | 4.6 | 20 |
0.75 | 24/0.20 | 0.6 | 5.0 | 26 |
1.0 | 32/0.20 | 0.6 | 5.4 | 33 |
Size of conductor | Nominal Thickness Of insulation mm |
Nominal Thickness Of sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires No. /mm |
Upper Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.20 | 0.5 | 0.6 | 3.0X4.8 | 3.6X6.0 | 27 |
0.75 | 24/0.20 | 0.5 | 0.6 | 3.2X5.2 | 3.9X6.4 | 34 |
Size of conductor | Nominal Thickness Of insulation mm |
Nominal Thickness Of sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional Area mm2 |
Number and diameter of wires No. /mm |
Upper Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
Size of conductor | Nominal Thickness of insulation mm |
Nominal Thickness of Sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires No/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.2 | 0.5 | 0.6 | 5.0 | 6.2 | 44 |
0.75 | 24/0.2 | 0.5 | 0.6 | 5.4 | 6.8 | 55 |
Size of conductor | Nominal Thickness of insulation mm |
Nominal thickness of Sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires No. /mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 3.8*6.0 | 5.2*7.6 | 47 |
Size of conductor | Nominal Thickness of insulation mm |
Nominal Thickness of Sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional Area mm2 |
Number and diameter of wires No/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
Size of conductor | Nominal thickness of insulation mm |
Mean overall diameter Upper limit mm |
Approx. Net weight per km Kg |
|
Nominal Cross-sectional area mm2 |
Number and diameter of wires No. /mm |
|||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Size of conductor | Nominal thickness Of insulation mm |
Size of Earth- Conduct -ivity Conductor No/mm |
Nominal thickness Of sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires mm |
Lower limit mm |
Upper Limit mm |
||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*9.6 | 4.7*11.0 | 92 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*10.5 | 5.4*12.5 | 115 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*12.5 | 6.2*14.5 | 170 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.1 | 5.8*14.5 | 7.4*18.0 | 255 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*16.5 | 8.0*20.0 | 340 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*21.0 | 9.6*25.5 | 550 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*24.5 | 11.0*29.5 | 790 |
Size of conductor | Nominal Thickness Of insulation mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross-sectional area mm2 |
Number and diameter of wires No/mm |
Lower Limit mm |
Upper Limit mm |
||
0.5 | 28/0.15 | 0.8 | 2.5X5.0 | 3.0X6.0 | 24 |
0.75 | 42/0.15 | 0.8 | 2.7X5.4 | 3.2X6.4 | 29 |
Size of conductor | Nominal Thickness Of insulation mm |
Mean overall diameter Upper limit mm |
Approx. Net weight per km Kg |
|
Nominal Cross-sectional area mm2 |
Number and diameter of wire No/mm |
|||
0.5 | 16/0.20 | 0.6 | 2.6 | 10 |
0.75 | 24/0.20 | 0.6 | 2.8 | 13 |
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5* | 30/0.25 | 0.7 | 3.5 | 20 |
2.5* | 50/0.25 | 0.8 | 4.2 | 32 |
4.0* | 56/0.30 | 0.8 | 4.8 | 49 |
Size of conductor | Nominal Thickness Of insulation mm |
Mean overall diameter of Each core Upper limit mm |
Approx. Net weight per km Kg |
|
Nominal Cross-sectional area mm2 |
Number and diameter of wires mm |
|||
0.5 | 16/0.20 | 0.6 | 4.6 | 20 |
0.75 | 24/0.20 | 0.6 | 5.0 | 26 |
1.0 | 32/0.20 | 0.6 | 5.4 | 33 |
Size of conductor | Nominal Thickness Of insulation mm |
Nominal Thickness Of sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires No. /mm |
Upper Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.20 | 0.5 | 0.6 | 3.0X4.8 | 3.6X6.0 | 27 |
0.75 | 24/0.20 | 0.5 | 0.6 | 3.2X5.2 | 3.9X6.4 | 34 |
Size of conductor | Nominal Thickness Of insulation mm |
Nominal Thickness Of sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional Area mm2 |
Number and diameter of wires No. /mm |
Upper Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
Size of conductor | Nominal Thickness of insulation mm |
Nominal Thickness of Sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires No/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.2 | 0.5 | 0.6 | 5.0 | 6.2 | 44 |
0.75 | 24/0.2 | 0.5 | 0.6 | 5.4 | 6.8 | 55 |
Size of conductor | Nominal Thickness of insulation mm |
Nominal thickness of Sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional area mm2 |
Number and diameter of wires No. /mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 3.8*6.0 | 5.2*7.6 | 47 |
Size of conductor | Nominal Thickness of insulation mm |
Nominal Thickness of Sheath mm |
Mean overall dimensions | Approx. Net weight per km Kg |
||
Nominal Cross- Sectional Area mm2 |
Number and diameter of wires No/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
JING XIN provides Duplexer serier products incuding filter,duplexer and combiner. Diplexers are available for FM, VHF, CDMA, LTE, GSM, AWS, PCS, AMPS, DCS, UMTS, WALAN. X-Band.All the products` frquency can be customized from 50MHZ to 40GHz.
LC Duplexers/Diplexers are available in 2 to 10 sections with bandwidth ranging from 5 to 100%.
The components are chosen for the best performance at the required frequencies of operation.
The Duplexer/Diplexer size will depend greatly on the power handling, the required insertion loss,
and the number of sections.The standard designs are 0.05dB Chebyshev response.
Other response type such as Butterworth, Elliptic, Bessel as well as special filter shapes are also available.
The size of the duplexer/diplexer will vary depending on the specifications and power requirement.
Power filters are also available with power handling capability as high as 500W.
All packages can be manufactured in different styles, suitable for the frequency range of the filter.
Lc Duplexer,Lc Structure Combiner,Customized Lc Structure,Lc Structure Diplexer,Surface Spray Paint Duplexer,Low Power Duplexer
CHENGDU JING XIN MICROWAVE TECHNOLOGY CO., LTD , http://www.cdjx-microwave.com